Altair Embed 2022.3

Description

Altair Embed 2022.3.

Release Notes Altair Embed 2022.3
These Release Notes cover four products: Altair Embed, Altair Embed Basic, Altair Embed SE, and Altair Embed Viewer. They include new features and enhancements, known issues, and resolved simulation and code generation issues.

Description
Creates unique y-axis labels for multiple subDescriptions
PolarDescription
Zooms in to a specific time segment
Compile pop-up command
Compiles the selected compound block based on the settings in the Tools > Code Gen dialog
Texas Instruments target support
Expands target support to include F280039C, F2800137, and F2800157
Texas Instruments peripheral support
Expands eCAP support to include high resolution event capture and to use internal signals on devices as event capture input

Known GUI Issues
- If you choose Chrome as your Browser for Help, and Help opens in an empty window, close Chrome and then re-open Help
Known Simulation Issues
- ActiveX blocks are 32-bit and do not work with 64-bit applications
- OPC blocks are 32-bit and do not work with 64-bit applications
- Co-simulation with PSIM does not detect the modelsim co-sim element
- Raspberry Pi
. Embed supports only 32-bit OS on Raspberry Pi
. Under Examples > Embedded > Linux > Raspberry Pi > SPI, the following two diagrams produce incorrect temperature values: SPI0_TC77_RPi3BPlus and SPI1_TC77_RPiBPlus
Known Code Generation Issues
- Arduino: HIL for string outputs does not work
- Linux: Diagrams set up to run on Linux targets using the Target Interface block may show spikes in CPU utilization due to the multiprocess nature of how Linux processes are scheduled
- Raspberry Pi: HIL for string outputs does not work

Resolved GUI Issues
- AFT block: missing Help button in dialog
- Bezel block: Help button not pointing to correct Help location
- DLL error when invoking Embed SE
- Get AFT Parameter block: missing Help button in dialog
- Kafka blocks: Embed crashes
- Matrix Size block: missing text in dialog
- Description block: wrong trace style for trace6
- Set AFT Parameter block: missing Help button in dialog
- Viewer: unable to install 64-bit version

Resolved Simulation Issues
- Compound block internal connectors not saved when Stacked option is enabled
- Export block: fails when Background Output is enabled
- Import block: interpolation and extrapolation produce incorrect results
- FMU block: simulation error in model exchange
- JSON example: incorrect entry in Key/Values parameter
- Kafka block: crashes Embed
- Map 1D block: incorrect simulation results for single step
- Description block: incorrect y-axis label for nonuniform Descriptions
- PSIM Coupler block: does not work properly when Retain States is enabled

Resolved Code Generation Issues
These issues apply to Altair Embed and Altair Embed Basic; they do not apply to Altair Embed SE.
- ADC Config block: Reference drop-down missing 2022.3
- Code Generation Aborted pop-up message appears intermittently during code generation
- Conversion of non 16/32 bit fixed point to string not working properly
- Cortex M3 Blink example: missing file name in extern block
- Map block: extrapolation does not work for Raspberry Pi
- Matrix Constant block: throws compile error for all targets
- C2000: ePWM interrupts missing configuration information
- F28004x/F2837x/F28002x: XINT issue when GPIO is used
- Linux: dotProduct output incorrect
- ZynqSoc7000: compound block: matrix signal not aligning properly to SIM_STATE structure

Download